Back flow Device Required on Lawn & Garden Well Yes -- FCEC
Chlorination of New Well Required Yes -- KDHE A30
Chlorination of Well Required after Work on Well Yes -- KDHE A30
Cleanouts Required on Lateral Line Ends Yes -- KDHE 4-2
Cleanouts Required on Solid's Lines-Maximums
Every 100' -- FCEC
County Sanitary Code Adopted
Yes--09-13-1994
Depth: Lateral Line
Max 3'--FCEC
Depth: Septic Tank No Regulations
Depth: Well Head 1 Foot Above Grade--A30
Distance: Lateral to House Foundation 20'--FCEC
Distance: Between Lateral Lines Min. 6.5'--FCEC
Distance: Lagoon to House Foundation
Min. 50'--KDHE 4-2; FCEC
Distance: Lagoon to Property Line
Min. 50'--KDHE 4-2; FCEC
Distance: Lateral to Property Line 10'--FCEC
Distance: Septic System to Private Water Line
Min. 10'--KDHE 4-2; FCEC
Distance: Septic System to Public Water Supply Line
Min. 25'--KDHE 4-2
Distance: Septic System to Public Water Supply Well Min. 100'--KDHE 4-2
Distance: Septic Tank to House
Min. 10'--KDHE 4-2; FCEC
Distance: Septic Tank to Lateral Line Min. 10'--FCEC
Distance: Well to Confined Feeding Operation Min. 50'--KDHE A30
Distance: Well to Privy Min. 50'--FCEC
Distance: Well to Property Line Min. 25'--A30
Distance: Well to Septic System Min. 50'--KDHE 4-2, FCEC
Distance: Well to Sewer Line-Not Tight Construction Min.50'--KDHE 4-2, FCEC
Distance: Well to Source of Contamination
Min 50' -- KDHE A30
Distance: Well to Surface Water Min. 50'--KDHE A30
Inspection Required Before Wastewater System Covered
Yes--FCEC
Investigation of Septic System Complaints Yes--FCEC
Investigation of Well Complaints Yes--FCEC
Lateral Line Maximum Length
100'--KDHE 4-2; FCEC
Lateral Size Discount for Each Additional 250 Gal Capacity of Septic Tank
5%--FCPZ&EH(Conditional) FCEC
Lateral Size Discount for Effluent Filter
5%--FCPZ&EH
Lateral Size Discount for High Capacity Chambers
30%--FCPZ&EH (Conditional)
Lateral Size Discount for Standard Chambers
20%--FCPZ&EH (Conditional)
Lateral Trench Maximum Width
Max 4'--FCEC
Lateral Trench Minimum Width Min 18"--FCEC
Line From Septic Tank to Laterals/Chambers Schedule 40 or Greater--KDHE 4-2
Location of septic system within 100 year flood plain
Not Allowed--FCEC
Lot Size Minimum 2 Acres--FCEC
Manhole Access Required on Septic Tank
Required--KDHE 4-2
Perc Test Required for Lateral Sizing/Lagoon
Yes--FCEC
Permit Required for Domestic Water Well Yes-- $50.00 FCEC
Permit Required for Lawn & Garden Well Yes--$50.00 FCEC
Permit Required for Livestock Well
Yes--$50.00 FCEC
Permit Required for Privy Construction Yes--FCEC
Real Estate Inspection Required Before Property Transfer Yes--FCEC
Septage Hauler Required to Have Permit
Yes--FCEC
Septage Transport and Disposal Complaints
US EPA, KDHE, FCEC
Septic System Contractor Required to Have Permit
Yes--FCEC
Septic System Waiver Available From:
FCPZ & EH
Septic Tank Material, Approved Concrete, Polyvinyl, Fiberglass--KDHE 4-2
Septic Tank Size 1 Bedroom
1000 Gallon--KDHE 4-2
Septic Tank Size 2 Bedroom 1000 Gallon--KDHE 4-2
Septic Tank Size 3 Bedroom 1000 Gallon--KDHE 4-2
Septic Tank Size 4 Bedroom 1200 Gallon--KDHE 4-2
Septic Tank Size 5 Bedroom 1500 Gallon--KDHE 4-2
Septic Tank Size 6 Bedroom 1800 Gallon--KDHE 4-2
Slope Required for Chamber Laterals Level to 1/8" per Foot, KDHE 4-2
Slope Required for Pipe & Rock Lateral Line Level to 1/8" per Foot, KDHE 4-2
Slope Required for Solids Line
1/8" per foot to 1/4" per foot--KDHE 4-2
Solid's Line Material Under Traffic Area
Schedule 40 or Greater--KDHE 4-2
Subdivision Approval Required for Lot Size Yes-- FCEC
Surface Discharge of Gray Water Allowed No--KSA 65-17th and KDHE 4-2
Surface Discharge of Wastewater Allowed
No--KSA 65-17th and KDHE 4-2
Water Well Distance Waiver Available From: FCPZ & EH and KDHE A30
Well Work Only Allowed to be Performed By licence Well Driller & Property Owner Yes--KDHE A30
Setbacks:Rev 1, 12-13-07